The Maniks Sequential Controller has been designed to operate the MANIKS pilot valves used on dust collector Equipment. Light emitting diodes (LEDs) provide visual indication of which pilot valve is being energized as well as "Power On" indication. The number of sequenced steps is adjustable from 2 through 10.Controls are provided to adjust the length of time between valves being de-energized (Pulse Frequency / Off time) and the length of time that the valve is energized (Pulse Duration / On time). Silicon semiconductor components control all timing and logic Functions.
Two independent methods of starting and stopping the Controller are provided. The first method will automatically stop the sequence and reset the Controller to the first valve position whenever A. C. power is removed and then reconnected.
The second method is by a remote control contact connected to the terminals provided. When the remote contact is opened, the sequence stops. When the remote contact is reclosed, the sequence continues from the previous
The catalog SQP-1 Sequential Controller provides timed sequential energization of connected loads. When power is applied to the Controller, the "Power On" light emitting diode (LED) provides visual indication and pilot valve number 1 is immediately energized. "Output 1" LED provides visual indication of this event.
The pilot valve will remain energized for the length of time as indicated by the setting of the "Pulse Duration / On time" control. Note that the calibrated dials are for approximate settings only and if exact times are required, they must be measured.
Pilot valve number 2 will automatically be energized at some time interval after pilot valve number 1 has been de-energized. This length of time will be as indicated by the setting of the "Pulse Frequency / Off time" control, "Output 2” LED will provide visual indication that this event is occurring. The Controller will continue to sequentially energize the pilot valves until the power is removed.
Supply Voltage | Input Fuse |
---|---|
230VAC | 1.5A |
110VAC | 3A |
24VDC | 3A |
Voltage | Max Inrush Current | Constant Current |
---|---|---|
230 VAC | 4 Amp. (50 Hz.) | 2 Amp. (50 Hz.) |
110 VAC | 4 Amp. (50 Hz.) | 2 Amp. (50 Hz.) |
Input Voltage | Output Voltage |
---|---|
230 VAC | 24VDC |
110 VAC | 24VDC |
230 VAC | 110VAC |
The MANIKS Controllers of this series are micro controller based units which can be programmed to suit clients actual requirements. There are two basic modes of operation : a)Program Mode b)Manual Mode
In "program Mode" the unit can be programmed to follow desired set of instructions and in “Manual Mode “we can operate out put ( Pilot Valves ) sequentially. This controller has been designed to operate the pulse solenoid valves used on dust collector equipments.
The controller has been provided with SEEPROM to retain programmed values of various parameters in case of power failure. The programmed values automatically get stored in SEEPROM. This SEEPROM will last up to 1million read/write operations and the stored data will be retained up to many years.
The Micro Controller provides timed sequential energization of connected loads. When power is applied to the controller, pilot valve will remain energized for the length of time as indicated by the setting of the “ON”control.
By keeping MENU key on key board pressed for approx 3 Sec.We can select “PROGRAM MODE” for modification in values of various parameters.
Supply Voltage | Input Fuse |
---|---|
230VAC | 300m A. |
110VAC | 300m A. |
Input Voltage | Output Voltage |
---|---|
230VAC | 24 VDC |
110 VAC | 24 VDC |
A 15-point terminal block with approved means for connection of conductors without terminal lugs are provided on the Controller for convenient wiring of the control power, loads and remote contact (if used).
Figure 1 illustrates where all necessary wiring should be made, loads, should be wired in desired sequence as noted. ONLY after all connection has been re-checked, should power be applied to the Controller.
CAUTION: Switch off the controller before making any connection or adjustments. To CHANGE TIME INTERVALS TO CHANGE NUMBER OF LOAD STEPS Turn the Pulse Frequency dial To the desired setting. This is the Approximate time interval between Energizing load steps. Turn the Pulse Duration dial to the desired Setting. This is the approximate time Interval that each load is energized. Locate the Jumper wire connected between the circuit board and the step pin. pull off the jumper and push it into the desired pin number. This is the total number of load steps.